15114 Pre-flow pressure 1
15115 Pre-flow pressure 2
15116 Pre-flow pressure 3
Data type: Word
Unit of data: 0.01Mpa or 0.1 kg/cm
2
Range of data: 0 to 255
Set the assist gas pre-flow pressure.
15120 Processing flow pressure 1
15121 Processing flow pressure 2
15122 Processing flow pressure 3
Data type: Word
Unit of data: 0.01Mpa or 0.1 kg/cm
2
Range of data: 0 to 255
Set the assist gas processing flow pressure.
15126 After flow pressure 1
15127 After flow pressure 2
15128 After flow pressure 3
Data type: Word
Unit of data: 0.01Mpa or 0.1 kg/cm
2
Range of data: 0 to 255
Set the assist gas after-flow pressure.
15132 Maximum assist gas pressure
Data type: Word
Unit of data: 0.01Mpa or 0.1 kg/cm
2
Range of data: 0 to 255
Set an assist gas pressure (kg/cm
2
(Mpa)) at which 10V is output in
analog output.
15135 Assist gas pressure set time
Data type: Word
Unit of data: 10msec
Range of data: 0 to 32767