10.1 INPUT UNIT
10.1.1 Replacing the Stabilized Power Supply
Replace the stabilized power supply as follows:
(1) Turn off the power to the CNC, then turn off the power to the
laser oscillator. In addition, open the main circuit breaker for the
laser oscillator.
(2) Remove the IF PCB.
(3) Disconnect all cables from the stabilized power supply.
(4) Remove the four edge supports, then remove the stabilized
power supply.
(5) Install the new PCB by reversing the procedure used for
removal.
Connect the cables, noting the alignment marks. Ensure that no
terminals are loose.
10.1.2 Replacing the Input Unit Control PCB
(1) Turn off the power to the CNC, then turn off the power to the
laser oscillator. In addition, open the main circuit breaker for the
laser oscillator.
(2) Remove the IF PCB.
(3) Disconnect all cables from the control PCB.
(4) Remove the four edge supports, then remove the input unit
control PCB.
(5) Install the new PCB by reversing the procedure used for
removal.
Connect the cables, noting the alignment marks.
Check that the connectors are connected firmly.