B-70255EN/01 10.REPLACEMENT PROCEDURES
- 155 -
CAUTION
Usually, all oil is drained from a turbo blower prior to
shipping. Even so, however, the turbo blower must
not be inclined because trace amounts of oil will
inevitably remain inside the unit.
If a turbo blower is inclined, it can no longer be used.
Replacement procedure
Be careful not to damage the O-rings or their mating surfaces on the
pipes. A damaged O-ring or mating surface will result in gas leakage.
(1) Turn off the power to the CNC, then turn off the power to the
laser oscillator. In addition, open the main circuit breaker for the
laser oscillator.
(2) Disconnect the cooling water tubes and power cables from the
turbo blower, then drain the oil from the turbo blower.
(3) Disconnect the two pipes from the turbo blower outlet.
Cover the removed gas pipes and turbo blower to prevent dust
from entering.
(4) Remove the hexagon headed bolt which secures the damping
rubber and blower base, then remove the turbo blower by sliding
it horizontally. Note that the turbo blower weighs about 30 kg.
(5) Remove the two metal brackets, used to secure the turbo blower,
from the removed turbo blower, then mount them on the new
turbo blower.
(6) Mount the new turbo blower on the oscillator, then fix the gas
pipes. Be careful not to damage the O-rings and ensure that no
O-ring is missing.
(7) Tighten the nut of the damping rubber. Carefully follow the
procedure below to prevent the damping rubber from being
twisted and damaged.
(8) Connect the cooling water tubes and the power and ground
cables.
(9) Check that there are no cooling water leaks, turn on the oscillator,
then check for gas leakage.