B-70255EN/01 9.SETTING AND ADJUSTMENT
- 117 -
9.1.2 Base Discharge Adjustment
9.1.2.1 Rewriting the parameter
Rewrite the parameters according to the table below. (Upon
completion of adjustment, return the parameters to the original
values.)
Table 9.1.2.1 Parameters to be modified before starting adjustment
CNC parameters Settings
PRM15000 bit 4, PRM15201 0(1)
(Output compensation disable)
PRM 15208 0(2)
(Laser power feedback disable)
PRM 15207,15210,15212 Maximum command. (See Table 2)(3)
(Maximum output power setting)
PRM 15223 2850(4)
(Bias command value)
NOTE
For the setting of the other parameters, follow the
data sheet.
9.1.2.2 Base Discharge Adjustment
(1) Start the oscillator, and wait until the gas pressure is stabilized in
the base discharge state.
(Wait about 3 minutes. See DGN 905.)
(2) Then, check that all discharge tubes are continuously discharging.
If a discharge tube stops discharge, turn VR11 of the power
supply corresponding to the discharge tube clockwise until the
discharge tube discharges.
(3) Turn VR11 counterclockwise slowly to set the state where all of
the four discharge tubes are about to stop main discharge.
(4) Record the value of RFI.----------------------------------------------(a)
(5) Turn VR11 counterclockwise to adjust the value of RFI to a
value lower than the electric shutter adjustment value. (See
Table 2.)
(6) Turn off HV and set 2790 in PRM 15223 for specifying a bias
command value. (See Appendix B.)
(7) Check that trigger electrode discharge lasts for five minutes in
the base discharge state. If discharge is turned off, turn VR11 of
the power supply clockwise slowly, and increase the value of
RFI by 4 mA or increase the value of DCV by 0.7 V. After