B-70255EN/01 APPENDIX D.PARAMTER LIST
- 213 -
D.4 PARAMETERS FOR EDGE MACHINING CONDITIONS
15050 Edge detection angle
Data type: Word
Unit of data: deg
Range of data: 0 to 180
A corner is assumed to be present when the angle formed by two
blocks is smaller than the specified angle.
15051 Peak piercing power value
Data type: Word
Unit of data: W
Range of data: 0 to 7000
Set a peak power value for piercing to be performed at the top of a
corner.
15052 Piercing pulse frequency
Data type: Word
Unit of data: Hz
Range of data: 5 to 2000
Set a pulse frequency for piercing to be performed at the top of a
corner.
15053 Piercing pulse duty ratio
Data type: Word
Unit of data: %
Range of data: 0 to 100
Set a pulse duty ratio for piercing to be performed at the top of a
corner.
15054 Piercing time
Data type: Two-word
Unit of data: msec
Range of data: 0 to 99999999
Set a piercing time used for piercing to be performed at the top of a
corner.
15055 Piercing assist gas pressure
Data type: Word
Unit of data: 0.01Mpa or 0.1 kg/cm
2
Range of data: 0 to 255
Set an assist gas pressure for piercing to be performed at the top of a
corner.