B-70255EN/01 4.INSTALLATION
- 47 -
4.4.3 Electrical Connections
Connect the cables to the laser oscillator as described below.
(1) Power cable
U(R)
V(S)
W(T)
Power supply: 200VAC +10% 50/60Hz ±1Hz 3f -15%
or 220VAC +10% 60Hz ±1Hz 3f -15%
(2) Ground cable
Connect the ground cable to the ground connection section
(class 1 : Ground resistance is 10 ohms or less.)
(3) Signal cables
When a metallic cable (shorter than 10 m) is used:
Connect the cable to IF JD1B.
(Connect jumper pin LINK1 of IF to the JD1 side.)
When an optical fiber cable (10 m or longer) is used:
Connect the cable to IF COP1B.
(Connect jumper pin LINK1 of IF to the COP side.)
(4) Signal lines
(a) Emergency stop input signals (ESP1, ESP2)
(b) OFF prohibit signals (OFI1,OFI2) - (EOF,COM) CNC side
A contact
(c) Laser power supply ON/OFF signal (CP1A) - CNC-
controlled 24 VDC
4.4.4 Inter-unit Connections
The C1000iA has an oscillator section and exhaust pump section.
Interconnection is made according to the procedure described below.
(1) Connection of the exhaust pump power cable
Use the supplied cable. Connect it correctly (with the correct
phase sequence).
(2) Gas piping
Use the supplied gas pipe and joints.