1. DISPLAY AND OPERATION
B–64115EN/01
84
710 Error status of first spindle
DGN
711 Error status of second spindle
DGN
[Data type] Word
712 Warning status of first spindle
DGN
713 Warning status of second spindle
DGN
[Data type] Word
If an error (the yellow LED flashes and the error number appears) or
warning occurred in the αi spindle amplifier module (SPM), the number
is displayed on the diagnostic screen.
When there is no error or warning, ”0” is indicated.
NOTE
1 For spindles older than the αi spindle, this function is invalid.
2 When the system configuration of the spindle (even another
spindle) includes an additional spindle older than the αi
spindle, this function is invalid.
Refer to the FANUC SERVO MOTOR αi series Maintenance Manual
(B–65285EN) for errors on the αi spindle.
See Subsection 10.1.4, ”Warning Interface for the αi Spindle” in this
manual for warnings.
D Error and warning
statuses of the αi spindle