1. DISPLAY AND OPERATION
B–64115EN/01
68
NOTE
1 The temperature data must fall within the following ranges.
50_C to 160_C "5_C
160_C to 180_C "10_C
2 The temperature at which an overheat alarm is issued has
a maximum error of 5_C.
3 Information on axes other than the αi servo axis is not
indicated. (Indicated by ”0_C.”)
#7
310
#6
DTH
#5
ALP
#4
NOF
#3
BZ2
#2
BZ1
#1
PR2
#0
PR1
DGN
#0(PR1): The setting of the following parameters has been changed: Parameters
1821, 1850, 1860, 1861.
#1(PR2): The setting of the ATS bit (bit 1 of parameter 8302) has been changed.
#2(BZ1): The detected APC battery voltage is 0 V (Inductosyn).
#3(BZ2): The detected APC battery voltage is 0 V (separate position detector).
#4(NOF): The Inductosyn output no offset data.
#5(ALP): Before the α pulse coder detects a full single rotation, reference position
establishment by parameters was attempted.
#6(DTH): A controlled axis detach signal/parameter was input.
#7
311
#6
DUA
#5
XBZ
#4
GSG
#3
AL4
#2
AL3
#1
AL2
#0
AL1
DGN
#0(AL1): An APC alarm was issued.
#2(AL3): The detected APC battery voltage is 0 V (serial pulse coder).
#3(AL4): An abnormal rotation speed (RCAL) was detected.
#4(GSG): The G202 signal was brought from 0 to 1.
#1(AL2): A disconnection was detected.
#6(DUA): While the dual position feedback function was being used, the difference
in error between the semi–closed loop side and the closed loop side
became too large.
#5(XBZ): The detected APC battery voltage is 0 V (serial separate position
detector).
D Cause of the APZ bit (bit
4 of parameter 1815)
brought to 0