1. DISPLAY AND OPERATION
B–64115EN/01
34
The system alarm history screen (detail screen) displays information
items such as registers and stacks involved when a system alarm is issued.
The following items are displayed:
1. System alarm occurrence date and time
2. System alarm number
3. System alarm message (No message is displayed for some system
alarms.)
4. System alarm occurrence series and edition
5. Number of display pages
6. General–purpose resistor, pointer index register, segment register,
task register, LDT register, flag register, interrupt source, error
code, error address
7. Contents of stacks (up to 32 stacks)
8. Contents of stacks of privilege level 3 (up to 48 stacks)
9. NMI information
You can switch among the information items 6 to 9 by the page keys
PAGE
PAGE
.
Pressing the [RETURN] soft key returns the screen display to the state
alarm history list screen.
SYSTEM ALARM HISTORY O1234 N12345
2 2002–03–11 07:23:07 D4B1–01(1/4)
973 NON MASK INTERRUPT
EAX EBX ECX EDX
00000000 00930063 000003E0 00000040
ESI EDI EBP ESP
00000010 009404E0 0000FFB4 0000FFDC
SS DS ES FS GS TR LDTR
06D8 0338 0248 0440 0338 0628 0028
EFLAGS VECT ERRC ERROR–ADDRESS
00003046 FFFF 0000 03E0:000009BC
EDIT **** *** *** 08:20:52
[ SELECT ][ RETURN ][ CLEAR ][ ][ ]
(Detail display screen 1)
1.4.2.3
System alarm history
screen (detail screen)