E. FSSB START–UP PROCEDURE/
MATERIALS
B–64115EN/01
APPENDIX
644
D AXIS NO: Controlled axis number
The controlled axis numbers set in parameter Nos. 1920 through 1929
are displayed.
When a value outside the range 1 to the maximum number of
controlled axes is set, 0 is displayed.
D NAME: Controlled axis name
The axis name set in the parameter No. 1020 corresponding to a
controlled axis number is displayed. When the controlled axis number
is 0, – is displayed.
D As amplifier information, the following information items are
displayed:
S UNIT: Type of servo amplifier unit
S SERIES: Servo amplifier series
S CURRENT: Maximum current value
D As separate detector interface unit information, the information items
below are displayed.
S EXTRA
The character M, which stands for “separate detector interface
unit,” is followed by the ordinal number of a separate detector
interface unit counted from the separate detector interface unit
closest to the CNC.
S TYPE
The type of a separate detector interface unit is displayed by a letter.
S PCB ID
The ID of a separate detector interface unit is displayed using four
digits in hexadecimal. For a separate detector module (8 axes),
DETECTOR (8AXES) is displayed after the separate detector
interface unit ID. For a separate detector module (4 axes),
DETECTOR (4AXES) is displayed after the separate detector
interface unit ID.
The axis setting screen displays axis information.
(AXIS SETTING) O1000 N00001
M1 M2 Cs
1 X A1–L 0 00 01
2 Y A1–M 1 0 1 0 0
3 Z A2–L 0 0 0 1 0
4 A A3–L 0 0 0 0 2
5 B A3–M 0 0 0 0 0
6 C A4–L 0 0 0 0 0
>_
MDI **** *** *** 13:11:56
[ AMP ][ AXIS ][ MAINT ][ ][ (OPRT) ]
E.8.2
Axis Setting Screen