6. DIGITAL SERVO
B–64115EN/01
382
1) Amplifier setting screen
The amplifier setting screen consists of two sections: the first section
displays information about the slave, while the second section
displays information about the pulse modules.
AMPLIFIER SETTING O1000 N00001
NO. AMP SERIES UNIT CUR. AXIS NAME
1 A1–L α SVM–HV 40AL 1 X
2 A1–M α SVM 12A 2 Y
3 A2–L β SVM 40A 3 Z
4 A3–L α SVM 20A 4 A
NO. EXTRA TYPE PCB ID
5 M1 A 0000 DETECTOR(8AXES)
6 M2 B 12AB
>_
MDI **** *** *** 13:11:56
[ AMP ][ AXIS ][ MAINTE ][ ][(OPRT)]
The amplifier setting screen consists of the following items:
D NO. (slave number)
The numbers of up to ten slaves (up to eight amplifiers and up to two
pulse modules) connected via the FSSB are displayed sequentially,
with the one nearest to the CNC being number 1.
D AMP (amplifier type)
The amplifier type display consists of the letter A, which stands for
“amplifier,” a number that indicates the placing of the amplifier, as
counted from that nearest to the CNC, and a letter such as L (first axis)
or M (second axis) indicating the placing of the axis in the amplifier.
D AXIS NO. (controlled axis number)
The axis number of each controlled axis specified in parameters (Nos.
1920 to 1929) is displayed. If a number specified in these parameters
falls outside the range of between 1 and the maximum number of
controlled axes, 0 is displayed.
D NAME (controlled axis name)
The axis name assigned to a parameter (No. 1020) corresponding to
a particular controlled axis number is displayed. If the controlled axis
number is 0, – is displayed.
D The following items are displayed as amplifier information:
⋅ UNIT (servo amplifier unit type)
⋅ SERIES (servo amplifier name)
⋅ CURRENT (maximum rating)
D The following items are displayed as pulse module information:
⋅ SEPARATE
This display consists of the letter M, which stands for “pulse
module” and a number indicating the placing of the pulse module,
as counted from that nearest to the CNC.
⋅ TYPE
This display is a letter indicating the type of the pulse module.