8. TROUBLESHOOTING
B–64115EN/01
454
#7
G0008
#6 #5 #4
ERS
#3 #2 #1 #0
#7(ERS) : When the bit is 1, external reset signal is input.
This signal is usually used for a confirmation signal of M02 when an M02
is specified in a program as the end of a program.
Therefore, when M02 is executed, this signal is input.
An automatic operation is put into a reset status when RESET key on the
MDI panel is pressed.
#7
G0008
#6
RRW
#5 #4 #3 #2 #1 #0
#6(RRW) : When this signal is 1, the reset & rewind signal is input.
This signal is usually used for a confirmation signal of M30 when an M30
is specified in a program as the end of a program.
Therefore, when M30 is executed, this signal is input.
When any servo alarm has generated, cycle operation is put into the reset
state and operation stop.
The cycle operation becomes feed hold state in the following cases:
1) Modes are switched from an automatic operation mode to a manual
operation mode.
2) Feed hold signal is input.
<Mode select signal>
#7
G0043
#6 #5 #4 #3 #2
MD4
#1
MD2
#0
MD1
memory edit(EDIT) 0 1 1
Automatic operation (MEM) 0 0 1
Manual data input (MDI) 0 0 0
Jog feed (JOG) 1 0 0
Handle/step 1 0 1
operation
TEACH IN HANDLE 1 1 1
TEACH IN JOG 1 1 0
<Feed hold signal>
#7
G0008
#6 #5
*SP
#4 #3 #2 #1 #0
#5(*SP) : When this signal is 0, the feed hold signal is input.
#7
G0046
#6 #5 #4 #3 #2 #1
SBK
#0
#1(SBK) When this signal is 1, the single block signal is input.
b.External reset signal is
input
c. Reset button on the MDI
is pressed
d.Reset & rewind signal is
input
e. Servo alarm has
generated
f. Cycle operation is in a
feed hold state
g.It become single block
stop during automatic
operation