APPENDIX
B–64115EN/01
A. ALARM LIST
531
Number ContentsMessage
307 APC alarm: nth–axis battery low 1 nth–axis (n=1 – 8) axis APC battery voltage reaches a level where the
battery must be renewed.
APC alarm. Replace the battery.
308 APC alarm: nth–axis battery low 2 nth–axis (n=1 – 8) APC battery voltage has reached a level where the
battery must be renewed (including when power is OFF).
APC alarm .Replace battery.
309 APC ALARM:
n AXIS ZRN IMPOSSIBL
Return to the origin has been attempted without first rotating the motor
one or more times. Before returning to the origin, rotate the motor one
or more times then turn off the power.
Number Message Description
330 INDUCTOSYN:DATA ALARM The absolute–position data (offset data) from Inductosyn cannot be
detected.
331 INDUCTOSYN:ILLEGAL PRM Parameter No. 1874, 1875, or 1876 is set to 0.
No. Message Description
360 n AXIS : ABNORMAL CHECKSUM
(INT)
A checksum error occurred in the built–in pulse coder.
361 n AXIS : ABNORMAL PHASE DATA
(INT)
A phase data error occurred in the built–in pulse coder.
362 n AXIS : ABNORMAL REV.DATA
(INT)
A rotation speed count error occurred in the built–in pulse coder.
363 n AXIS : ABNORMAL CLOCK (INT) A clock error occurred in the built–in pulse coder.
364 n AXIS : SOFT PHASE ALARM (INT) The digital servo software detected invalid data in the built–in pulse
coder.
365 n AXIS : BROKEN LED (INT) An LED error occurred in the built–in pulse coder.
366 n AXIS : PULSE MISS (INT) A pulse error occurred in the built–in pulse coder.
367 n AXIS : COUNT MISS (INT) A count error occurred in the built–in pulse coder.
368 n AXIS : SERIAL DATA ERROR
(INT)
Communication data from the built–in pulse coder cannot be re-
ceived.
369 n AXIS : DATA TRANS. ERROR
(INT)
A CRC or stop bit error occurred in the communication data being
received from the built–in pulse coder.
380 n AXIS : BROKEN LED (EXT) The LED of separate detector is erroneous.
381 n AXIS : ABNORMAL PHASE
(EXT LIN)
A phase data error occurred in the separate linear scale.
382 n AXIS : COUNT MISS (EXT) A pulse error occurred in the separate detector.
383 n AXIS : PULSE MISS (EXT) A count error occurred in the separate detector.
384 n AXIS : SOFT PHASE ALARM
(EXT)
The digital servo software detected invalid data in the separate de-
tector.
385 n AXIS : SERIAL DATA ERROR
(EXT)
Communication data from the separate detector cannot be received.
386 n AXIS : DATA TRANS. ERROR
(EXT)
A CRC or stop bit error occurred in the communication data being
received from the separate detector.
387 n AXIS : ABNORMAL ENCODER
(EXT)
An error occurs in the separate detector. For details, contact the
manufacturer of the scale.
(4) Inductsyn alarms
(5) Serial pulse coder
(SPC) alarms