7. AC SPINDLE (SERIAL INTERFACE)
B–64115EN/01
412
Numerals are parameter numbers :
S11:
1st Main
S12:
1st Sub
S21:
2nd Main
S22:
2nd Sub
Proportional gain(HIGH) 4044 4210 4044 4210
Proportional gain(LOW) 4045 4211 4045 4211
Integral gain(HIGH) 4052
4052
Integral gain(LOW) 4053
4053
Position loop gain(HIGH) 4065
4065
Position loop gain(MID,HIGH) 4066 4066
Position loop gain(MID,LOW) 4067
4067
Position loop gain(LOW) 4068 4068
Motor voltage 4085 4238 4085 4238
Acc./Dec. time constant 4032 4032
Shift amount 4034 4034
Numerals are parameter numbers :
S11:
1st Main
S12:
1st Sub
S21:
2nd Main
S22:
2nd Sub
Proportional gain(HIGH) 4044 4210 4044 4210
Proportional gain(LOW) 4045 4211 4045 4211
Integral gain(HIGH) 4052
4052
Integral gain(LOW) 4053
4053
Position loop gain(HIGH) 4065
4065
Position loop gain(MID,HIGH) 4066 4066
Position loop gain(MID,LOW) 4067
4067
Position loop gain(LOW) 4068 4068
Motor voltage 4085 4238 4085 4238
ZRN gain % 4091 4239 4091 4239
Grid shift amount 4073 4223 4073 4223
D Synchronization control
mode
D Rigid tapping mode