B–64115EN/01
7. AC SPINDLE (SERIAL INTERFACE)
417
If an error occurs (a yellow LED lights and an error number is displayed)
on the αi spindle amplifier, the error state is displayed on the diagnosis
screen.
710 First–spindle error state
711 Second–spindle error state
730 Third–spindle error state
731 Fourth–spindle error state
The error number for an error on an individual spindle amplifier is
indicated.
If no error occurs, “0” is indicated.
NOTE
– If the system contains an old–type spindle amplifier (such
as one for an α spindle), no spindle amplifier error is
indicated.
– Refer to the αi Servo Motor Maintenance Manual and the
like for details of the spindle amplifier errors.
7.1.5
αi Spindle Error State
Messages
General
Diagnosis screen