B–64115EN/01
1. DISPLAY AND OPERATION
47
Mode selection signals and rapid traverse override signals
are displayed as indicated below:
Input signal
MD1 ND2 MD4 REF DNC1
0 0 0 0 0 MDI
1 0 0 0 0 MEM
1 0 0 0 1 RMT
0 1 0 0 0 NOMODE
1 1 0 0 0 EDT
0 0 1 0 0 H/INC
1 0 1 0 0 JOG
1 0 1 1 0 REF
0 1 1 0 0 TJOG
1 1 1 0 0 THND
Input signal
ROV1 ROV2
0 0 R100%
1 0 R50%
0 1 R25%
1 1 RF0%
(3)NC alarms
NC alarms are displayed in reverse video.
P/S alarms, system alarms, and external alarms are displayed together
with their numbers.
For other types of alarms, only the alarm type is displayed. (No details
are displayed.)
(4)Time stamp (date and time)
The following time data (date and time) is recorded:
1) Date and time of power–on
2) Date and time of power–off
3) Date and time when an NC alarm occurs
4) The clock time is recorded at predetermined intervals, together
with each new calendar day.