B–64115EN/01
1. DISPLAY AND OPERATION
69
#7
CFE320
#6 #5 #4
ERP
#3
OPN
#2
RDY
#1
OPP
#0
CLS
DGN
Indicates the internal status of the FSSBC.
#0(CLS): Closed.
#1(OPP): Running OPEN protocol.
#2(RDY): Open and ready.
#3(OPN): Open.
#4(ERP): Running ERROR protocol.
#7(CFE): Encountered configuration error.
(The actual slave type does not match the one specified in the conversion
table.)
#7
XE3321
#6
XE2
#5
XE1
#4
XE0
#3
ER3
#2
ER2
#1
ER1
#0
ER0
DGN
Indicates the cause of an FSSBC error.
#0(ER0): INFORMED ERROR
#1(ER1): (RESERVE)
#2(ER2): Master port disconnection
#3(ER3): External EMG input
Indicates the cause of an FSSBC error resulting from a request from a slave.
#4(XE0): (RESERVE)
#5(XE1): Slave port disconnection
#6(XE2): Master port disconnection
#7(XE3): External EMG input
#7
330
#6 #5 #4 #3
EXT
#2
DUA
#1
ST1
#0
ST0
DGN
#7
332
#6 #5 #4 #3
EXT
#2
DUA
#1
ST1
#0
ST0
DGN
#7
348
#6 #5 #4 #3
EXT
#2
DUA
#1
ST1
#0
ST0DGN
to
#0, #1(ST0, ST1): Indicates the type code for an actually connected slave.
ST1 ST0 Type Address
0 0 A Servo amplifier
0 1 (B: RESERVE) (Currently nonexistent)
1 0 C Stand–alone type detector inter-
face unit
1 1 (RESERVE) (Currently nonexistent)
D FSSB status