B-63943EN/02 5.CONNECTION TO CNC PERIPHERALS
- 99 -
Cable Wires
Many cables without a shield (UTP cables) are commercially available
as twisted pair cables conforming to 10BASE-T or 100BASE-TX.
To improve noise immunity in factory automation environments,
however, be sure to use twisted pair cables (STP cables) with a
common shield in category 5.
Recommended cables (for fixed parts)
Manufacturer Specification Remark
Furukawa Electric Co., Ltd. DTS5087C-4P Twisted wires
Nissei Electric Co., Ltd. F-4PFWMF Single-wire cable
NOTE
No cable recommended for use in fixed sections
shall be used in movable sections. Be sure to use
the following movable-section cables.
Recommended cable (for movable sections)
Manufacturer Specification Remark
Oki Electric Cable
Co., Ltd.
AWG26 4P TPMC-C5-F(SB) Dedicated to
FANUC products
Cable specification (FANUC original product, with no connector)
Drawing number: A66L-0001-0453
Manufacturer: Oki Electric Cable Co., Ltd.
Specification
- Electrical characteristic:
Complying with EIA/TIA 568A categories 3 and 5
The length of the cable to the hub must be kept within 50 m
because of its attenuation performance.
- Structure: Common-shield braided cable with drain wire
The conductors of the cable are AWG26 annealed-copper
strand wire, with a sheath 0.8 mm thick and an outer
diameter of 6.7 ± 0.3 mm
- Fire resistance: UL1581 VW-1
- Oil resistance:
As per FANUC's internal standard (Equivalent to
conventional oil-resistant electrical cable)
- Flex resistance:
Million or more bending cycles with a bending radius of 50
mm (U-shaped bend test)
- UL style No.: AWM20276 (80°C/30V/VW-1)
NOTE
Use the TM21CP-88P(03) connector made by
Hirose Electric Co., Ltd. to this cable.