A. MACRO PROGRAM EXAMPLE
B–61803E–1/10
APPENDIX
220
No
Routine
Name
Program
number
Explanation
1 DDPL O9501 Data display to cursor position
2 CDPL O9502 Cursor display
3 KEYIN O9503 Key input control
4 VDPLX O9504 One- row display of variable data
5 VDPLY O9505 One- column display of variable data
6 DSPC O9506 Screen CLEAR
7 VSET O9507 Data setting to continuous variable area
8 VCOPY O9508 Variable copy
In standard routine, the following variable area is used.
In user’s program, do not use this area for others purposes.
P-CODE variables #100 - #109
#139 - #148
Common variables #10000 - (up to the variables required)
(1) P-CODE variable
#149
#139
#148
#100
1
2
3
4
5
CSNO
Vacant
KCONT
KDATA
CPNT
SUBP
9
Spare
Work
area
Spare
Cursor control No. of screen being now selected
Key input control data (#8501 value)
Key input numerical data (#8503 value)
Cursor pointer (0,1, 2, .......)
Cursor subpointer (0,1, 2, .......)
For macro call using
T code (RESERVE)
A.3
STANDARD MACRO
PROGRAM
A.3.1
Standard Routine List
A.3.2
Area of Variable Used
A.3.3
Explanation of Variable
Area