B–61803E–1/10
APPENDIX
E. FANUC Super CAP T/CAP II T MACRO
COMPILER/EXECUTOR (Series 16/18)
and Super Capi T Macro Compiler/
EXECUTOR (Series 16i/18i/21iT)
339
D Single Action II (when bit 0 of parameter No.9766 is 0) <available on Ver.3>
+ 0 Process number +30 Unused
+ 1 Unused +31 Unused
+ 2 System utilization area (∗3) +32 Unused
+ 3 Machining type (∗4) +33 Unused
+ 4 Type (∗29) +34 Unused
+ 5 Tool post (Spindle axis selection) (∗6) +35 Unused
+ 6 Execution cycle (∗7) +36 Unused
+ 7 Unused +37 Unused
+ 8 Unused +38 Unused
+ 9 Unused +39 Unused
+10 Unused +40 Unused
+11 Unused +41 Unused
+12 Unused +42 Unused
+13 Unused +43 Unused
+14 Tool number +44 Unused
+15 T code +45 Unused
+16 Unused +46 Unused
+17 Unused +47 Unused
+18 Unused +48 Run hour
+19 Unused +49 Unused
+20 Unused +50 Unused
+21 Unused +51 Unused
+22 Unused +52 * First variable number for roughing
+23 Unused +53 * First variable number for finishing
+24 Unused +54 * First variable number for chamfering
+25 Unused +55 * First variable number of a figure block
+26 Unused +56 * Unused
+27 Unused +57 * Use status flag (0: Not used, 1: Used)
+28 Unused +58 * First variable number of the preceding process
+29 Unused +59 * First variable number of the next process
F: Ver.2 or later, J: Ver.3 or later, (
*
?): See the note below.
NOTE
Some item names depend on the version.
* : System management area –
Avoid data writing by a user program.
If there are no processes corresponding to +52 to +59, or if the current
process corresponds to any of those processes, the area is set to null
or 0.