B–61803E–1/10
APPENDIX
E. FANUC Super CAP T/CAP II T MACRO
COMPILER/EXECUTOR (Series 16/18)
and Super Capi T Macro Compiler/
EXECUTOR (Series 16i/18i/21iT)
426
#7 #6 #5 #4 #3 #2 #1 #0
Compile parameter
9003 TCF
#7 (TCF) 0: The special function for entering conversational
programs is not used.
1: The function for entering conversational programs is
used.
H Be sure to set this bit to 1.
#7 #6 #5 #4 #3 #2 #1 #0
Compile parameter
9007 MFOPT TFOPT TTVR2
#2 (TTVR2) 0: Extended special P-code variables No. 20000 and after
are separated for head 1 and head 2.
1: Extended special P-code variables No. 20000 and after
are shared by head 1 and head 2.
H Be sure to set this bit to 0 when Super CAP T Ver.
1 is used for the Series 16-TTA.
#6 (TFOPT) 0: The conversational programming function for the
Series 16-T/TTA is not used.
1: The conversational programming function for the
Series 16-T/TTA is used.
H Be sure to set this bit to 1.
#7 (MFOPT)0: The conversational programming function for the
Series 16-MA is not used.
1: The conversational programming function for the
Series 16-MA is used.
H Be sure to set this bit to 0.
#7 #6 #5 #4 #3 #2 #1 #0
Compile parameter
9009 CM30 LM30
#1 (LM30) 0: Does not use all 30 lines during VGA display.
1: Uses all 30 lines during VGA display.
H Set this bit to 0.
#2 (CM30) 0: Does not use all 30 lines during VGA display.
1: Uses all 30 lines during VGA display.
Compile parameter
9021 G code (1 to 999) which calls the P-code program No. O9018
The macro program used in the auxiliary process is assigned P-code
program No. O9018 in FANUC Super CAP.
Compile parameter
9022 G code (1 to 999) which calls the P-code program No. O9019
The macro program used in the auxiliary process is assigned P-code
program No. O9010 in FANUC Super CAP.
Compile parameter
9037 Number of special P-code variables No. 10000 and after to be used
H Be sure to set this bit to 7.