2. MACRO COMPILER AND MACRO
EXECETOR
B–61803E–1/10
PROGRAMMING
22
#7 #6 #5 #4 #3 #2 #1 #0
No.
0121 ASI SB2
Data type: Bits
This parameter must be set when I/O CHANNEL = 2. The meanings of
the bits correspond to those of the bits in parameter 101.
No.
0122 Number of the I/O device (when I/O CHANNEL = 2)
Data type: Bytes
Specify the number of the I/O device when I/O CHANNEL = 2 according
to Table 1.
No.
0123 Baud rate (when I/O CHANNEL = 2)
Data type: Bytes
Specify the baud rate for the I/O device when I/O CHANNEL = 2
according to Table 2.
#7 #6 #5 #4 #3 #2 #1 #0
No.
8701 PLD
Data type: Bits
PLD In the P-code loader for the macro compiler or executor, the RAM
is:
0 : Cleared with OMM and rewritten.
1 : Not cleared with OMM, but overwritten.
Message Explanation
EXECUTOR OPTION NOTHING A macro executor option is not yet selected.
I/O OPTION NOTHING Reader/punch control 1 option is not yet selected.
I/O OPTION (CH2) NOTHING Reader/punch control 2 option is not yet selected.
ILLEGAL CHANNEL A channel other than channel 1 or 2 is selected.
ILLEGAL CHARACTER The transmitted data is not correct.
OVERRUN Overrun error
FRAMING ERROR Framing error
DSR SIGNAL OFF Communication error
PARITY ERROR Data without parity was transmitted.
CHECK SUM ERROR Checksum error
2.1.6.4
Alarms