FANUC AC SPINDLE MOTOR a series
2. FUNCTION EXPLANATION
B–65160E/02
132
Parameter No.
Description
0T Description
16i/16
15TT
0TT
1st
Description
16i/16
2nd1st
0TT
2nd
0576 0576 5811 4811
Error pulse difference between the two spindles for
issuing an alarm while spindle synchronization is
applied
6532 6672 6532 3032 3172 4032
Acceleration/deceleration time constant used for spindle
synchronization control
(The same value must be set for both the 1st and 2nd
spindles.)
6533 6673 6533 3033 3173 4033
Detection level for spindle synchronization completion
signal
6534 6674 6534 3034 3174 4034 Shift amount for spindle phase synchronization control
6535 6675 6535 3035 3175 4035 Compensation data for spindle phase synchronization
6544
6545
6684
6685
6544
6545
3044
3045
3184
3185
4044
4045
Velocity loop proportional gain for spindle
synchronization
(A parameter is selected by the CTH1A PMC DI signal.)
6552
6553
6692
6693
6552
6553
3052
3053
3192
3193
4052
4053
Velocity loop integral gain for spindle synchronization
(A parameter is selected by the CTH1A PMC DI signal.)
6506
#1
6646
#1
6506
#1
3006
#1
3146
#1
4006
#1
Gear ratio increment system
6556
to
6559
6696
to
6699
6556
to
6559
3056
to
3059
3196
to
3199
4056
to
4059
Spindle–to–motor gear ratio data
(A parameter is selected by the CTH1A and CTH2A
PMC DI signals.)
6565
to
6568
6705
to
6708
6565
to
6568
3065
to
3068
3205
to
3208
4065
to
4068
Position gain for spindle synchronization
(The same value must be specified for both the 1st and
2nd spindles.)
(A parameter is selected by the CTH1A and CTH2A
PMC DI signals.)
6506
#4
6646
#4
6506
#4
3006
#4
3146
#4
4006
#4
Setting to disable automatic one–rotation signal
detection in spindle synchronization mode switching
6507
#6
6647
#6
6507
#6
3007
#6
3147
#6
4007
#6
Setting of the function for detecting the position coder
signal error alarm (AL-47)
6585 6725 6585 3085 3225 4085 Motor voltage for spindle synchronization
6300 6480 6300 3480 3700 4336
Magnetic flux switching point used for calculating an
acceleration/deceleration time constant used for spindle
synchronization control
(The same value must be specified for both the 1st and
2nd spindles.)
6304 6484 6304 3484 3704 4340
Bell–shaped acceleration/deceleration time constant for
spindle synchronization
(The same value must be specified for both the first and
second spindles.)
6310 6490 6310 3490 3710 4346 Incomplete integration coefficient