B–65160E/02
3. EXPLANATION OF
PARAMETERS
FANUC AC SPINDLE MOTOR a series
209
16i/16 #7 #6 #5 #4 #3 #2 #1 #0015i15
RETSV POSC1 ROTA1
6140 3320 3176 4176
6320 3540
Standard setting: 0 0 0 0 0 0 0 0
ROTA1: Indicates the relationship between the rotation directions of spindle and
spindle motor.
0: Rotates the spindle and spindle motor in the same direction.
1: Rotates the spindle and spindle motor in the reverse direction.
POSC1: Indicates the mounting direction of position coder.
0: Rotates the spindle and position coder in the same direction.
1: Rotates the spindle and position coder in the reverse direction.
RETSV: Indicates reference point return direction (rigid tap/spindle positioning
etc.) when in servo mode.
0: Spindle reference point returns CCW (counter clockwise)
1: Spindle reference point returns CW (clockwise)
16i/16 #7 #6 #5 #4 #3 #2 #1 #0015i15
MGSEN POSC2 MRDY1
6141 3321 3177 4177
6321 3541
Standard setting: 0 0 0 0 0 0 0 1
MRDY1:Determines whether the MRDYA signal (machine ready signal) is used
or not.
0: Not used. (The MRDYA signal should be always set to 1.)
1: Used.
POSC2: Determines whether the position coder signal is used or not.
0: Not used.
1: Used.
MGSEN:Indicates the mounting direction of magnetic sensor.
0: Rotates the motor and magnetic sensor in the same direction.
1: Rotates the motor and magnetic sensor in the reverse direction.
3.3
SUB SPINDLE
PARAMETERS FOR
SPINDLE SWITCHING
CONTROL