B–65160E/02
3. EXPLANATION OF
PARAMETERS
FANUC AC SPINDLE MOTOR a series
199
Delay time for motor excitation
6599 3099 3099 4099
6739 3239
Standard setting : 0
Parameter for setting the time until motor excitation is stable in rigid tap
and Cs contouring control modes.
16i/1615 15i0
Base speed of motor power specifications
6600 3100 3100 4100
6740 3240
Base speed of motor power specifications
Conventional
HRV
16i/1615 15i0
Limit value for motor power specifications
6601 3101 3101 4101
6741 3241
Torque limit value for motor power specifications
Conventional
HRV
16i/1615 15i0
Base speed
6602 3102 3102 4102
6742 3242
Activating voltage saturation speed at no–load
Conventional
HRV
16i/1615 15i0
Magnetic flux down start speed
6603 3103 3103 4103
6743 3243
Base speed limit ratio
Conventional
HRV
16i/1615 15i0
Current loop proportional gain data
6604 3104 3104 4104
6744 3244
Current loop proportional gain data
Conventional
HRV
16i/1615 15i0
Current loop proportional gain data (in Cs contouring control)
6605 3105 3105 4105
6745 3245
Conventional
HRV
16i/1615 15i0
Current loop integral gain data
6606 3106 3106 4106
6746 3246
Current loop integral gain data
Conventional
HRV
16i/1615 15i0
Current loop integral gain data (in Cs contouring control)
6607 3107 3107 4107
6747 3247
Conventional
HRV
16i/1615 15i0
Current loop integral gain zero point
6608 3108 3108 4108
6748 3248
Current loop integral gain zero point
Conventional
HRV