B–65160E/02
3. EXPLANATION OF
PARAMETERS
FANUC AC SPINDLE MOTOR a series
211
PCPL2 OthersMZ sensor,
BZ sensor
(Built–in sensor)
PCTYPEPCPL0PCPL1
0 1 0 0 512 l/rev (f205) ––
0 1 0 1 64 l/rev (f26) ––
1 1 0 0 384 l/rev (f154) ––
16i/16 #7 #6 #5 #4 #3 #2 #1 #0015i15
BISGAN RFTYPE EXTRF
6144 3324 3180 4180
6324 3544
Standard setting: 0 0 0 0 0 0 0 0
EXTRF: Specifies whether a reference switch signal is used.
0: Not used.
1: Used.
RFTYPE: Specifies whether to invert the external one–turn signal.
0: The final signal is to be inverted.
1: The final signal is not to be inverted.
BISGAN:
Specifies the built–in sensor of motor model a0.5 (9D00.D).
0: Other than the case below (α0.5 (B380))
1: Motor model a0.5 (B390) with MZ sensor
16i/16 #7 #6 #5 #4 #3 #2 #1 #0015i15
BLTRGD ALGOVR SPDUNT GRUNIT
6146 3326 3182 4182
6326 3546
Standard setting: 0 0 0 0 0 0 0 0
GRUNIT:
Gear ratio setting resolution setting
0: 1/100 units (Under normal circumstances, set to ”0”.)
1: 1/1000 units
These parameters change the following parameter settings.
Parameter No.
0 15
Description
1st 2nd 1st 2nd
15
16
/16
6180
6181
6360
6361
3360
3361
3580
3581
3216
3217
4216
4217
Gear ratio
(HIGH)
Gear ratio
(LOW)