APPENDIX
A. SPINDLE PARAMETER TABLE
B–65160E/02
310
FS0 Internal
data
number
F–xxx
Classi-
fica-
tion
Application
Contents
Standard
initial
setting
data
FS16i
/16
FS15i
FS15
1st
Spindle
Internal
data
number
F–xxx
Classi-
fica-
tion
SUB
low
speed
SUB
high
speed
MAIN
low
speed
MAIN
high
speed
Contents
Standard
initial
setting
data
FS16i
/16
FS15i
2nd
Spindle
1st
Spindle
2nd
Spindle
6517#2 6657#2 3017#2 3157#2 3017#2 4017#2 0 Whether to use the
position coder one–
rotation signal detection
function during normal
rotation
f f
B 008#2
6517#3 6657#3 3017#3 3157#3 3017#3 4017#3 0 Whether to use the
position coder one–
rotation signal detection
function during orienta-
tion by magnetic sensor
f f
B 008#3
6517#4 6657#4 3017#4 3157#4 3017#4 4017#4 0 008#4
6517#5 6657#5 3017#5 3157#5 3017#5 4017#5 0 008#5
6517#6 6657#6 3017#6 3157#6 3017#6 4017#6 0 008#6
6517#7 6657#7 3017#7 3157#7 3017#7 4017#7 0 Whether to use the
short–cut function dur-
ing orientation from
stopped state
f f
B 008#7
6518#0 6658#0 3018#0 3158#0 3018#0 4018#0 0 009#8
6518#1 6658#1 3018#1 3158#1 3018#1 4018#1 0 009#9
6518#2 6658#2 3018#2 3158#2 3018#2 4018#2 0 009#10
6518#3 6658#3 3018#3 3158#3 3018#3 4018#3 0 009#11
6518#4 6658#4 3018#4 3158#4 3018#4 4018#4 0 Whether to use the a
sensor Cs contour con-
trol function
f f
B 009#12
6518#5 6658#5 3018#5 3158#5 3018#5 4018#5 0 Whether to use the ve-
locity command com-
pensation function dur-
ing high–speed orienta-
tion
f f
B 009#13
6518#6 6658#6 3018#6 3158#6 3018#6 4018#6 0 Whether to use the
high–speed orientation
function
f f
B 009#14
6518#7 6658#7 3018#7 3158#7 3018#7 4018#7 0 009#15
6519#0 6659#0 3019#0 3159#0 3019#0 4019#0 0 Conventional: Whether
to compensate dead
zone in Cs contour con-
trol mode and during
orientation
f f
B 009#0
HRV:
6519#1 6659#1 3019#1 3159#1 3019#1 4019#1 0 009#1
6519#2 6659#2 3019#2 3159#2 3019#2 4019#2 1 Whether to use torque
clamp at zero speed
f f
C 009#2
6519#3 6659#3 3019#3 3159#3 3019#3 4019#3 0 009#3
6519#4 6659#4 3019#4 3159#4 3019#4 4019#4 0 Setting of winding
switching condition dur-
ing output switching
f f
B 009#4
6519#5 6659#5 3019#5 3159#5 3019#5 4019#5 0 Conventional: Setup of
the DC link voltage
detection filter
f f
B 009#5
HRV:
6519#6 6659#6 3019#6 3159#6 3019#6 4019#6 0 009#6
6519#7 6659#7 3019#7 3159#7 3019#7 4019#7 0 Automatic parameter
setting function
f f
B 009#7