FANUC AC SPINDLE MOTOR aC series
1. ADJUSTMENT
B–65160E/02
260
(1) Check the input signal.
(a) Torque limit command (TLMH)
16i/16 #7 #6 #5 #4 #3 #2 #1 #0015i15
TLMHA
G229 G227 G070
(2) Check the paramter setting.
0 15 16 Description Setting data
6540
to
6541
3040
to
3041
4040
to
4041
Velocity loop
proportional gain on
normal operation
Set larager
value(1 to 3times)
6548
to
6549
3048
to
3049
4048
to
4049
Velocity loop integral
gain on normal
operation
Set larger
value(1 to 4times)
6583 3083 4083 Motor voltage setting
on normal operation
Set larger value( set-
ting value = 60 to 80 )
(1) Check the parameter setting.
(a) Acceleration/Deceleration time constant parameter. ( In case of
this data is too small, the Acceleration/Deceleration time is
increased. )
0 15 16 Description
6569
to
6572
3069
to
3072
4069
to
4072
Acceleration/Deceleration time constant
The initial setting of this parameter is 900 (min
–1
/sec).
Please set and adjust this parameter depends on the motor output
torque and spindle inertia.
Please refer to the section of parameter explanation (Subsec.
1.2.5) in details.
(b) Limitation of regenerative power
(In case of this data is too small, the deceleration time is
increased.)
0 15 16i/16 Description
6580 3080 4080 Limitatiion of regenerative power
(2) Check the DI signal
(a) Torque limit command (TLMH)
16i/16 #7 #6 #5 #4 #3 #2 #1 #0015i15
TLMHA
G229 G227 G070
1.3.6
The Cutting Capability
is Sub–standard
1.3.7
Acceleration/decelerati
on Time is Too Long