B–65160E/02
A. SPINDLE PARAMETER TABLE
APPENDIX
309
FS0 Internal
data
number
F–xxx
Classi-
fica-
tion
Application
Contents
Standard
initial
setting
data
FS16i
/16
FS15i
FS15
1st
Spindle
Internal
data
number
F–xxx
Classi-
fica-
tion
SUB
low
speed
SUB
high
speed
MAIN
low
speed
MAIN
high
speed
Contents
Standard
initial
setting
data
FS16i
/16
FS15i
2nd
Spindle
1st
Spindle
2nd
Spindle
6514#1 6654#1 3014#1 3154#1 3014#1 4014#1 0 Whether to use the
spindle switching func-
tion during SUB spindle
rotation
f f f f
B 007#9
6514#2 6654#2 3014#2 3154#2 3014#2 4014#2 0 Confirmation of MCC of
both MAIN and SUB of
spindle switching
f f f f
B 007#10
6514#3 6654#3 3014#3 3154#3 3014#3 4014#3 0 Confirmation of MCC of
both HIGH and LOW of
output switching
f f f f
B 007#11
6514#4 6654#4 3014#4 3154#4 3014#4 4014#4 0 Whether to use the
function for orientation
by both the position
coder and the magnetic
sensor
f f f f
B 007#12
6514#5 6654#5 3014#5 3154#5 3014#5 4014#5 0 Whether to use the
slave operation function
f f f f
B 007#13
6514#6 6654#6 3014#6 3154#6 3014#6 4014#6 0 Whether to use the
orientation function dur-
ing spindle synchro-
nization
f f f f
B 007#14
6514#7 6654#7 3014#7 3154#7 3014#7 4014#7 0 007#15
6515#0 6655#0 3015#0 3155#0 3015#0 4015#0 0 Whether to use the
spindle orientation func-
tion
f f f f
B 007#0
6515#1 6655#1 3015#1 3155#1 3015#1 4015#1 0 Whether to use the
spindle load monitor
function
f f f f
B 007#1
6515#2 6655#2 3015#2 3155#2 3015#2 4015#2 0 Whether to use the out-
put switching function
f f f f
B 007#2
6515#3 6655#3 3015#3 3155#3 3015#3 4015#3 0 007#3
6515#4 6655#4 3015#4 3155#4 3015#4 4015#4 0 007#4
6515#5 6655#5 3015#5 3155#5 3015#5 4015#5 0 007#5
6515#6 6655#6 3015#6 3155#6 3015#6 4015#6 0 007#6
6515#7 6655#7 3015#7 3155#7 3015#7 4015#7 0 007#7
6516#0 6656#0 3016#0 3156#0 3016#0 4016#0 0 008#8
6516#1 6656#1 3016#1 3156#1 3016#1 4016#1 0 008#9
6516#2 6656#2 3016#2 3156#2 3016#2 4016#2 0 008#10
6516#3 6656#3 3016#3 3156#3 3016#3 4016#3 0 Whether to use the
smoothing function dur-
ing feed–forward con-
trol
f f
B 008#11
6516#4 6656#4 3016#4 3156#4 3016#4 4016#4 0 Setting of control char-
acteristics in Cs con-
tour control mode
f f
B 008#12
6516#5 6656#5 3016#5 3156#5 3016#5 4016#5 0 Whether to use one–
rotation signal mis-
detection (AL–39) func-
tion of detector for Cs
contour control
f f
B 008#13
6516#6 6656#6 3016#6 3156#6 3016#6 4016#6 0 Whether to use a one–
rotation signal mis-
detection (AL–46) func-
tion of the position cod-
er signal
f f
B 008#14
6516#7 6656#7 3016#7 3156#7 3016#7 4016#7 0 Setting of the one–rota-
tion signal detection
condition
f f
B 008#15
6517#0 6657#0 3017#0 3157#0 3017#0 4017#0 0 008#0
6517#1 6657#1 3017#1 3157#1 3017#1 4017#1 0 008#1