B–65160E/02
3. EXPLANATION OF
PARAMETERS
FANUC AC SPINDLE MOTOR a series
215
16i/16 #7 #6 #5 #4 #3 #2 #1 #0015i15
PWM3K DS5 DS4 DS3 DS2 DS1 ESEC
6153 3333 3189 4189
6333 3553
Standard setting: 0 0 X X X X 0 0
X: Depends on the amplifier model.
ESEC : Setting of detection edge of position coder one rotation signal
0: CCW=Rising edge CW=Falling edge (Normally set to ”0”)
1: CCW, CW=Rising edge
DS5–DS1:
Set the current dead band data.
PWM3K:
Sets a PWM carrier frequency in the low–speed range when speed
range switching is used.
The value to be set in this parameter varies with the motor model.
Usually, set 0.
16i/16 #7 #6 #5 #4 #3 #2 #1 #0015i15
RFCHK3 RFCHK2 FFSMTH
6156 3336 3192 4192
6336 3556
Standard setting: 0 0 0 0 0 0 0 0
FFSMTH:
Presence of smoothing function on feedforward control
1: Without smoothing function
0: With smoothing function
Sets the presence of smoothing function on feedforward control of
servo mode (rigid tap, spindle positioning etc.).
RFCHK2:
Presence of 1 rotation signal error detection (AL-46) function for
position coder signal
0: 1 rotation signal error detection (AL-46) function not present
1: 1 rotation signal error detection (AL-46) function present
RFCHK3:
Presence of function for redetecting the 1 rotation signal for the
position coder signal each time spindle orientation/spindle
synchronization control/rigid tap zero return mode is entered.
0: The 1 rotation signal is not detected each time the operating mode
changes.
Once the 1 rotation signal has been detected, it is not detected
again until the power goes off.
1: The 1 rotation signal is detected each time the operating mode
changes.