FANUC AC SPINDLE MOTOR aC series
3. EXPLANATION OF
PARAMETERS
B–65160E/02
280
X: Depends on the motor model
ADJG: Setting of acceleration and deceleration judging conditions on
maximum output when accelerates and decelerates
X: Depends on the motor model
16i/16
#7 #6 #5 #4 #3 #2 #1 #0
0
15i
15
DS4 DS3 DS2 DS1 ESED ESEC
6513 3013 3013 4013
6653 3153 3153
Standard setting: 0 0 X X X X X 0
ESEC:
0: CCW=Rising edge CW=Falling edge (Normally set to ”0”)
1: CCW, CW=Rising edge
DS4-DS0:
Setting of current dead band data
Depends on the spindle amplifier module
16i/16
#7 #6 #5 #4 #3 #2 #1 #0
0
15i
15
ORIENT
6515 3015 3015 4015
6655 3155 3155
Standard setting: 0 0 0 0 0 0 0 0
ORIENT:
Presence of spindle orientation function (CNC software option)
0: Without spindle orientation function
1: With spindle orientation function
16i/16
#7 #6 #5 #4 #3 #2 #1 #0
0
15i
15
RFCHK3 RFCHK2
6516 3016 3016 4016
6656 3156 3156
Standard setting: 0 0 0 0 0 0 0 0
RFCHK2:
Precence of one rotation signal error detection function for positon
coder signal
0: One rotation signal error detection function (AL–46) not present.
1: One rotation signal error detection function (AL–46) present.
RFCHK3:
Presence of function for redetection the one rotation signal for the
position coder signal each time spindle orientation/spindle
synchronization mode is entered.
0: The one rotation signal is not detected each time the operating
mode changes (Once the one rotation signal has been detected, it is
not detected again until the power goes off)
1: The one rotation signal is detected each time the operating changes.