B-63784EN-1/01 OPERATION 4.AUTOMATIC OPERATION
- 129 -
[ Q TYPE ]
1 Turn the program restart switch on the machine operator's panel
ON.
2 Press key to display the desired program.
3 Find the program head.
4 Press the [PROGRAM RESTART] soft key then the
[(Q_SEQ#)] soft key, enter the sequence number of a block you
want to restart, then press the [EXEC] soft key. (Go to step 3.)
If the same sequence number appears more than once, the location
of the target block must be specified. Specify a frequency and a
sequence number. Specify a frequency then a sequence number.
Separate them with a comma ",".
To search only a sequence number in a specific
program (e.g. when a subprogram is called several
times during a search for a sequence number in a
specific subprogram), first specify from which
sequence number program execution is to be
restarted, then specify sequence number delimited
by "," and specify "O" follows by the program
number delimited by ",".
However, note that when the frequency is set to "1"
or the program number need not be specified, the
number of repeats and program number can be
omitted.
Q x x x x x x x x [EXEC]
Sequence number
Q x x x , x
x x x x x x x [EXEC]
Frequency
Sequence number
Q x x x , x
x x x x x x x , O x x x x x x x x [EXEC]
Frequency
Sequence number
Program number
PROG