B-63784EN-1/01 OPERATION 9.SETTING AND DISPLAYING DATA
- 369 -
- Skipping of tools
Among the tools registered in a specified group, the tool to be selected
next is skipped.
Method 1
(1) Press the [SKIP] soft key.
(2) Enter a group number.
(3) Press the [EXEC] soft key.
Method 2
(1) Enter a group number.
(2) Press the [SKIP] soft key.
Tool life management (group editing)
Tool life management data can be edited when MDI mode is set, and
the automatic operation stop state, automatic operation halt state, or
reset state (not during a reset) is set. However, tool life management
data cannot be edited while data is being set by a program. The
following editing operations are possible:
- Setting of service life count type, service life values, counter, and
tool data (T code, H code, D code)
- Addition of tool groups
- Addition of tool numbers (T code)
- Deletion of tool groups
- Deletion of tool data (states, T code, H code, D code)
- Setting for tool skip
- Setting for tool clearing (restart of service life)
NOTE
1 Editing must not be performed for the group for
which life count operation is to be started with the
next M06 command, or for that group for which life
count operation is being performed. Otherwise, the
life management of the group is terminated forcibly.
2 When any of the following editing operations is
performed, the tool change signal may be set to 1:
- Tool skip setting for the last tool
- Tool number deletion from a tool group resulting
in the tool group containing only those tools
whose lives have expired, as well as skipped
tools
3 When any of the following editing operations is
performed, the tool change signal may be set to 0:
- Tool number addition to a tool group resulting in
the tools whose lives have not expired being set
in the tool group
- Setting for tool clearing