B-63784EN-1/01 OPERATION 9.SETTING AND DISPLAYING DATA
- 329 -
Setting parameters
- Mode setting
Select MDI mode, or enter the emergency stop state by pressing the
emergency stop button.
- Setting parameter PWE
On the setting parameter screen, set bit 0 (PWE) of parameter No. 8000
for allowing setting input to 1.
For the method of setting, see Section II-9.3, "Displaying and setting of
setting parameters."
-Positioning the cursor
Position the cursor to the parameter you want to set.
Method 1
Using the page keys and the cursor keys,
position the cursor.
Method 2
(1) Press the [NUMBER SEARCH] soft key.
(2) Key in a parameter number.
(3) Press the [EXEC] soft key.
Method 3
(1) Key in a parameter number.
(2) Press the [NUMBER SEARCH] soft key.
- Entering settings (absolute input)
Method 1
(1) Press the [INPUT] soft key.
(2) Enter a number you want to set.
(3) Press the [EXEC] soft key.
Method 2
(1) Enter a number you want to set.
(2) Press the [INPUT] soft key.
Method 3
(1) Enter a number you want to set.
(2) Press the key.
PAGE
PAGE
INPUT