8.EDITING PROGRAMS OPERATION B-63784EN-1/01
- 250 -
- Outputting specified multiple programs
Locked/unlocked Results
Locked Those programs that fall outside the protected
range are output as usual.
For those programs that fall within the
protected range, SR0581 alarm "ENCODE
ALARM (PARAMETER)" is output.
Unlocked When all of the specified programs fall outside
the protected range, they are output as usual.
When all the specified programs fall within the
protected range, they are output as encoded
programs.
When some of the specified programs fall
within the protected range, while others do not,
SR0581 alarm "ENCODE ALARM
(PARAMETER)" is output.
Password not set The program is output in a normal way.
- Inputting an un-encrypted program
Locked/unlocked Results
Locked If the program is outside the security range, it is
input.
If it is within the security range, it is not input.
Unlocked, or password
not set
The program is input.
- Inputting an encrypted program
Password set in the
system and password of
the program
Results
Password set in the
system
Alarm SR580 ENCODE ALARM (PSWD&KEY)
is issued.
Password for the
program
The program is input.
Password not set in the
system
The program is input.
The PSW in the file is set for parameter No.
2210.
- Collating a program with an un-encrypted program
The program is always collated.
- Collating a program with an encrypted program
Password set in the
system and password of
the program
Results
Password set in the
system
Alarm SR580 ENCODE ALARM (PSWD&KEY)
is issued.
Password set in the
system = Password of
the program, or
password not set in the
system
The program is collated.