9.SETTING AND DISPLAYING DATA OPERATION B-63784EN-1/01
- 420 -
Setting the coordinates of diagonal vertexes
- Setting mode
Set MDI mode.
- Moving the cursor
Position the cursor to the coordinate field of a desired area number by
using the cursor keys .
- Inputting values
(Absolute input)
Method 1
(1) Press soft key [INPUT].
(2) Enter the value you want to set.
(3) Press soft key [EXEC].
Method 2
(1) Enter the value you want to set.
(2) Press soft key [INPUT].
Method 3
(1) Enter the value you want to set.
(2) Press the key.
- Inputting values
(Incremental input)
Method 1
(1) Press soft key [+INPUT].
(2) Enter the value by which the current setting is to be increased
or decreased.
(3) Press soft key [EXEC].
Method 2
(1) Enter the value by which the current setting is to be increased
or decreased.
(2) Press soft key [+INPUT].
- Inputting values
(Soft key input)
Move the cursor to X1 or Y1, or X2 or Y2 of the area number for which
you want to set the current machine coordinates, then press soft
key [AREA SETTING].
NOTE
After soft key [AREA SETTING] is pressed, the
cursor is automatically positioned to the next
coordinate.
INPUT