B-63784EN-1/01 OPERATION 9.SETTING AND DISPLAYING DATA
- 407 -
(1) Parameter input
Enter the parameter using the following procedure.
(1) Select EDIT mode. (Terminate background editing.)
(2) Select a slave axis for which the parameter is to be input.
(3) Press soft key [READ PM -> NC].
(4) Pressing soft key [EXEC] completes parameter input.
Pressing soft key [CANCEL] cancels parameter input.
The status message [READ] appears and blinks during parameter
input.
NOTE
If a program corresponding to the selected program
number is already in program memory, the new data
overwrites the program. If the program is currently
selected, however, no overwriting occurs. Instead, a
warning is issued to reject editing.
(2) Parameter output
Output the parameter using the following procedure.
(1) Select EDIT mode. (Terminate background editing.)
(2) Select a slave axis for which the parameter is to be output.
(3) Press soft key [PUNCH NC -> PM].
(4) Pressing soft key [EXEC] completes parameter output.
Pressing soft key [CANCEL] cancels parameter output.
Status message [PNCH] appears and blinks during parameter output.
Diagnosis screen
This screen displays diagnostic information.
Diagnostic data is represented in bit or integer (decimal) format. Refer
to the applicable power motion series connection manual for a detailed
explanation of the diagnostic data.