B-63784EN-1/01 OPERATION 10.DISPLAY
- 533 -
Parameter setting
Torque parameter screen
The parameters for the fine torque sensing function can be set on the
torque parameter screen.
On the torque graph screen, pressing the soft key [PARAMETER]
displays the torque parameter screen.
The torque parameter screen can be displayed only when the display is
provided with a graphics function.
Fig. 10.18. (d) Torque Parameter Screen
Display method
1 Display the torque graph screen, and place the soft keys in the
function selection state.
2 In the function selection state, press the soft key
[PARAMETER]. Then the torque parameter screen appears.
To redisplay the torque graph screen from the torque parameter
screen, press the soft key [SET END].
Torque parameters
With the torque parameter screen, you can enable or disable the sample
data preservation function, set the torque data store cycle, and set the
controlled axis numbers of target axes.
- Sample data save
Whether to enable or disable the sample data preservation function is
set. The setting is written in bit 2 (SPL) of parameter No. 4660.