B-63784EN-1/01 OPERATION 9.SETTING AND DISPLAYING DATA
- 363 -
Operation
- Positioning the cursor
Using the cursor keys , position the cursor.
The cursor keys
cannot be used.
- Turning on a switch
Method 1:Press the [ON:1] soft key.
Method 2:Press the numeric key
1
then the
INPUT
key.
Method 3:Press the numeric key
1
, then press the
[INPUT]
soft
key.
- Turning off a switch
Method 1:Press the [OFF:0] soft key.
Method 2:Press the numeric key
0
then the
INPUT
key.
Method 3:Press the numeric key
0
, then press the
[INPUT]
soft
key.
CAUTION
If a menu switch and the corresponding machine
signal are used at the same time, the input state is
the logical OR of both switches.
If a menu switch is turned off, but the corresponding
machine signal is on, for example, the actual input
state is on.