A.SETTING WHEN EDITION 07 OR EARLIER OF SERIES 6557 IS USED SUPPLEMENT B-62924EN/04
- 196 -
EndModule
Module = "24 Byte Out, 24 Byte In" 0xC0,0x17,0x17
EndModule
Module = "20 Byte Out, 20 Byte In" 0xC0,0x13,0x13
EndModule
Module = "16 Byte Out, 16 Byte In" 0xC0,0x0F,0x0F
EndModule
Module = "12 Byte Out, 12 Byte In" 0xC0,0x0B,0x0B
EndModule
Module = " 8 Byte Out, 8 Byte In" 0xC0,0x07,0x07
EndModule
Module = " 4 Byte Out, 4 Byte In" 0xC0,0x03,0x03
EndModule
Module = " 2 Byte Out, 2 Byte In" 0xC0,0x01,0x01
EndModule
Module = "32 Byte Out, 1 Byte In" 0xC0,0x1F,0x00
EndModule
Module = " 1 Byte Out, 32 Byte In" 0xC0,0x00,0x1F
EndModule
;
NOTE
For a FANUC slave station, Module in the GSD file
matches slave parameter CONFIG DATA. The
DI/DO sizes for a FANUC slave station can be
changed without restrictions as long as they do not
exceed 32/32 bytes. For this reason, all of the
values to be specified for Module cannot be listed.
For the values to be specified for Module, see the
explanation of CONFIG DATA in Table A-6 in
Supplement A.3, "Setting the Slave Parameters for