TITLE: Additional explanation of
PROFIBUS-DP Master function
(I/O Module Assignment function)
B-62924EN/04-1
FANUC LTD.
02.10.7
DRAW.NO.
NOTE
For the operation mode, pay careful attention to the following points:
(1) When the power is turned on in the status in which at least one slave
station is ACTIVE, the master station automatically becomes to the
OPERATE mode.
(2) In a case other than (1), that is, when the power is turned on in the
status in which all slave stations are not ACTIVE, the master station
automatically becomes to the STOP mode.
(3) A FANUC master station cannot manually be put in the OFFLINE
mode.
If a FANUC master station is in the OFFLINE mode immediately after
power-on, an error may occur. See Table 1-1, "Setting Error
Message."