5/42
SHEETDESCRIPTIONDESIGN DATE EDIT
01 Mutai Newl
re
istered
TITLE: Additional explanation of
PROFIBUS-DP Master function
(I/O Module Assignment function)
B-62924EN/04-1
FANUC LTD.
02.10.7
DRAW.NO.
A error message may be displayed at the lower left of Screen 1-2. In this case, take
appropriate action, referencing the table below.
Table 1-1 Error messages of Screen 1-2
Message Caution and action
“INVALID MASTER
PARAMETERS”
When CONTROL SOFTWARE is
changed from 6557 Series to 6558, this
message will appear.
In this case, please enter the soft key
[INI.AL], and turn the power off, then on
again.
“INVALID SLAVE EXISTS”
One or several invalid slaves exist.
The following reasons can be guessed.
-DI/DO size of a slave exceeds 244
bytes.
-An available slave does not exist.
-An invalid slave parameter is being
configured at a slave.
“ INVALID MODULE EXISTS”
One or several invalid modules exist.
Configure valid parameter referring to
“1.2.4 DI/DO Parameter Setting”, and
turn the power off, then on again.