B-62924EN/04 OPERATION 1.16i/18i/21i-A/B, Power Mate i-D/H, AND 16/18-C
- 39 -
NOTE
If either of the following messages is displayed on
Screen 1-10, take appropriate action corresponding
the message:
- "SET I/O SIZE[MAS+SLV<=256],POWER OFF"
When this node is shared by both master and slave
stations, the total of the DI/DO sizes for all slave
stations for which ENABLE is set and the DI/DO size
for the sharing slave station exceeds 256 bytes.
Set the DI/DO sizes again so that the total does not
exceed 256 bytes, and turn the power off, then on
again. (This message is displayed only when Edition
08 of series 6557 of CONTROL SOFTWARE is
used.)
- "UPGRADE SLAVE SOFTWARE"
Replace SLAVE SOFTWARE (series 6553 or 6551)
with Edition 07 or later of SLAVE SOFTWARE.
CAUTION
When assigning addresses, pay careful attention to the
following points:
1 Ensure that the specified DI and DO areas do not
overlap one another.
2 Ensure that specified addresses do not overlap an
area used for a ladder program.
3 Use the R area only. (When using the PMC-SB5, be
careful not to exceed R1499. When using the PMC-
SB6 or the PMC-NB6, be careful not to exceed
R2999.)