12/20
SHEETDESCRIPTIONDESIGN DATE EDIT
01 Hiramatsu Newl
re
istered
TITLE: PROFIBUS-DP Board OPERATOR’S MANUAL
Setting method of address mapping for
PMC-SD7“%I,%Q”
B-62924EN/04-3
FANUC LTD.
04.12.27
DRAW.NO.
A.3.1 Master Station Setting
If the following PMC address map is designed for DP-Master#1 (Series16i-B), the setting
examples of each setting screen are shown in the next pages.
Fig. PMC Address Map for DP-Master#1(Series16i-B)
%M00001
%M00033
%M00065
%M00161
%M00289
%M00417
%M00561
%M00609
%M00657
%M00097
%M00545
%M00705
%M00729
DI data from DP -Slave#3 (4bytes)
DI data from DP -Slave#4 (4bytes)
DI data from DP -Slave#5 (4bytes)
Not used
DO data to DP-Slave#3 (16bytes)
DO data to DP-Slave#4 (16bytes)
DO data to DP-Slave#5 (16bytes)
Not used
Diagnose data of DP-Slave#3 (6bytes)
Diagnose data of DP-Slave#4 (6bytes)
Diagnose data of DP-Slave#5 (6bytes)
Not used
Not used
Value of Operation mode (1byte)
%M00721
%M64000