B-63330EN/03 4.DESCRIPTION OF PARAMETERS
- 105 -
1627 FL feedrate for each axis for acceleration/deceleration during the threading
cycle
[Input type] Parameter input
[Data type] Realaxis
[Unit of data] mm/min, inch/min, degree/min (machine unit)
[Minimum unit of data] Depend on the increment system of the applied axis
[Valid data range] Refer to the standard parameter setting table (C)
(When the increment system is IS-B, 0.0 - +240000.0)
For each axis, set the FL feedrate used for acceleration/deceleration
during the threading cycle. Except in special cases, set this parameter
to 0.
NOTE
The time constant in parameter No. 1622 and the FL
feedrate in parameter No. 1623 are used during
normal threading (G33 (G32 in G code system A)).
1628 Time constant for rapid traverse acceleration/deceleration with constant
time for individual axes
[Input type] Parameter input
[Data type] Integeraxis
[Unit of data] msec
[Valid data range] 0 - 4000
Specifies the time constant for rapid traverse with constant time for
individual axes.
This parameter is effective only when bit 0 of parameter No. 1600
(REX) is set to 1.
1629 FL feedrate for rapid traverse acceleration/deceleration with constant time
for each axis
[Input type] Parameter input
[Data type] Realaxis
[Unit of data] mm/min, inch/min, degree/min (machine unit)
[Minimum unit of data] Depend on the increment system of the applied axis
[Valid data range] Refer to the standard parameter setting table (C)
(When the increment system is IS-B, 0.0 - +240000.0)
Specify the FL feedrate for rapid traverse acceleration/deceleration
with constant time along each axis.