B-63330EN/03 4.DESCRIPTION OF PARAMETERS
- 177 -
2454 Range of 2nd auxiliary function codes without buffering (1) (lower limit)
2455 Range of 2nd auxiliary function codes without buffering (1) (upper limit)
2456 Range of 2nd auxiliary function codes without buffering (2) (lower limit)
2457 Range of 2nd auxiliary function codes without buffering (2) (lower limit)
[Input type] Parameter input
[Data type] Integer
[Valid data range] 1 - 99999999
Specify the upper and lower limits of 2nd auxiliary function codes
without buffering. If the specified upper and lower limits are found to
be incompatible, the entered parameters are invalidated.
#7 #6 #5 #4 #3 #2 #1 #0
2458 MCL MER MZE M16
[Input type] Parameter input
[Data type] Bit
#0 M16 MDI operation is:
0: For the FS15 type.
1: For the FS16 type.
#5 MZE After the start of MDI operation, program editing during operation is:
0: Not inhibited.
1: Inhibited.
This setting is valid only when bit 0 (M16) of parameter No. (2458) is
set to 1.
#6 MER In single-block operation mode in MDI, when the last block of a
program has been executed, the executed program is:
0: Not erased.
1: Erased.
This setting is valid only when bit 0 (M16) of parameter No. 2458 is
set to 1.
NOTE
Even when this bit is set so that program erasure is
not performed, a program is erased if it is executed
with "%" (end of record) read. ("%" is inserted
automatically at the end of a program.)
#7 MCL When a reset is made, a program created in MDI mode is:
0: Not erased.
The cursor is placed at the end of the program after reset.
1: Erased.
This setting is valid only when bit 0 (M16) of parameter No. 2458 is
1.