B-63330EN/03 4.DESCRIPTION OF PARAMETERS
- 189 -
4734 Access size specification 2
[Input type] Parameter input
[Data type] Integer
[Valid data range] 0 - 4
In trace data 2 of waveform diagnosis function, the access size for the
tracing of specified memory is specified.
0: One byte (signed)
1: One byte (unsigned)
2: Two bytes (signed)
3: Two bytes (unsigned)
4: Four bytes (signed)
NOTE
If an illegal access size is specified, a system alarm
may be issued.
4735 Memory address specification 2
[Input type] Parameter input
[Data type] Integer
[Valid data range] 0 - 999999999
In trace data 2 of waveform diagnosis function, the memory address
for the tracing of specified memory is specified.
NOTE
Specify an existing address.
If an illegal address is specified, a system alarm may
be issued.
4736 Target board specification 3
[Input type] Parameter input
[Data type] Integer
[Valid data range] 0 - 1
In trace data 3 of waveform diagnosis function, the target board for
the tracing of specified memory is specified.
0: CNC main board
1: Customer’s board