B-63330EN/03 4.DESCRIPTION OF PARAMETERS
- 91 -
#7 FCC If, in acceleration/deceleration before look-ahead interpolation, there
is an axis for which the acceleration time is one second or longer:
0: The specified feedrate may not be attained because the precision
is important.
1: The specified feedrate will be attained because the feedrate is
important.
NOTE
When this parameter is set to 1, the precision of
curve interpolation such as circular and NURBS
interpolation may reduce.
1518 Minimum value of the feed-forward factor for automatic calculation
[Input type] Parameter input
[Data type] Integer
[Valid data range] 0 - 10000
Stores the minimum value of the feed-forward factor used for
automatic tuning. When automatic setting is performed on the HPCC
(SETTING) screen, the minimum value is automatically initialized to
94.0% (parameter value 9400) .
1519 Active parameter set number
[Input type] Parameter input
[Data type] Integer
[Valid data range] 0 - 2
Stores the current active parameter set. Usually, the active parameter
set is selected by pressing the [SLCT ACTIVE] soft key on the HPCC
(SETTING) screen and, therefore, this parameter need not be directly
specified.
1520 Finishing level (for finishing)
[Input type] Parameter input
[Data type] Integer
[Valid data range] 0 - 100
Stores the finishing level for the finishing parameter set. Usually, the
finishing level is entered from the HPCC (SETTING) screen and,
therefore, this parameter need not be directly specified.