4.DESCRIPTION OF PARAMETERS B-63330EN/03
- 34 -
#7 RMV For each axis, specifies whether to detach the shaft corresponding to
the control axis.
0: Do not detach.
1: Detach.
(Equivalent to the control axis detach signals DTCH1, DTCH2, and
so on.)
Effective when RMB (bit 7 of parameter No. 1005) is set to 1.
#7 #6 #5 #4 #3 #2 #1 #0
0013 DSL HDE HKE
[Input type] Setting input
[Data type] Bit
#4 HKE Specifies whether to store the history of key operations.
0: Do not store the history.
1: Store the history.
#5 HDE Specifies whether to store the history of DI/DO.
0: Do not store the history.
1: Store the history.
#6 DSL Specifies whether to display the system log screen.
0: Do not display the screen.
1: Display the screen.
#7 #6 #5 #4 #3 #2 #1 #0
0014 HD2
ASG FAN
[Input type] Setting input
[Data type] Bit
#1 FAN Specifies whether to ignore alarm FAN MOTOR STOP (OH002).
0: Do not ignore the alarm.
1: Ignore the alarm.
#4 ASG Specifies what compensation is to be changed in the Changing Active
Offset Value with Manual Move mode for offset memory B/C, as
follows:
0: Wear compensation
1: Geometry compensation
This parameter is valid for offset memory B/C.
#5 NIC Specifies whether to perform an interference check when
compensation plane switching occurs during three-dimensional cutter
compensation.
0: Perform.
1: Do not perform.
#7 HD2 Specifies whether the size of one file can exceed 2000 m when using
a floppy cassette, the PROGRAM FILE Mate, HANDY FILE, or FA
card.
0: Within 2000 m
1: Can exceed 2000 m