4.DESCRIPTION OF PARAMETERS B-63330EN/03
- 174 -
2410 Arc radius error limit value
[Input type] Setting input
[Data type] Real
[Unit of data] mm, inch (input unit)
[Minimum unit of data] Depend on the increment system of the reference axis
[Valid data range] 0 - 999999999
Specify a valid limit value as the difference between the radius value
at the start and end points for circular interpolation command.
Standard setting: 20
2411 M code 1 which does not put the following block in the buffer register
2412 M code 2 which does not put the following block in the buffer register
2413 M code 3 which does not put the following block in the buffer register
2414 M code 4 which does not put the following block in the buffer register
2415 M code 5 which does not put the following block in the buffer register
2416 M code 6 which does not put the following block in the buffer register
2417 M code 7 which does not put the following block in the buffer register
2418 M code 8 which does not put the following block in the buffer register
2419 M code 9 which does not put the following block in the buffer register
2420 M code 10 which does not put the following block in the buffer register
[Input type] Parameter input
[Data type] Integer
[Valid data range] 0 – 999999999
Specify M codes that do not put the following block in the buffer
register. If there is an M code whose next block should not be put in
the buffer register until the M function processing terminates in the
machine specify these M codes.
M00, M01, M02, and M30 are treated as M codes that do not put the
following block in the buffer register even though these parameters
are not specified for them. M98, M99, M codes set for parameters
Nos. 7071 to 7089, and those defined by parameters Nos. 7096, 7098,
7099, and 7010 are treated as M codes that put the following block in
the buffer register even though these parameters are specified for
them.